CRG-199 Module
Are you interested
in this product?
Description
Ref.: MDULCRG199
Electronic power load teaching module for power transformers and A.C. and D.C. rotary machines (single-phase and three-phase).
It has the ability to capture and control magnitudes by PC via a data acquisition system and DIANA software. The incorporated controls allow it to operate in accordance with the various types of passive loads:
- Direct current resistive load.
- Inductive load – resistive – single-phase capacitive.
- Inductive load – resistive –three-phase capacitive.
- Power factor variable between 0 and 1 (inductive and capacitive).
Functional description
The support comprises a triple-size training module: 250 x 216 x 130 mm.
It operates installed in a desktop vertical rack from where it gets its ± 15 V power required for operation. Interconnection with other modules in the test bench BNC-199 and DIANA software with a fast 26-pin connector.
2 mm sockets for external measurements and set values. 4 mm safety terminals input power (mains connection). Includes serigraph identifying the functional blocks. Has many advantages over other traditional load types (resistors, capacitor banks, inductances, etc.), Including the following:
- Reduced volume: all possible load types in one module.
- Improved Performance: Incorporates electronic circuitry which returns the energy to the power supply.
- Safety: Incorporates protection against overloads and short circuits, as well as safety terminals for user protection.
- Accuracy and resolution: Electronic control of electrical magnitudes (current amplitude and power factor).
- Instrumentation built into the module itself.
- Interconnection with other elements of the Test Bench BNC-199 tests and control from the PC with DIANA software.
- Possibility of autonomous operation with manual or computer assisted control (general purpose data acquisition system).
Technical specifications
Power supply | – Control: ± 15 VDC from the ALECOP support frame.
– Power: Single phase 190 to 250 Vac across safety terminals |
Maximum power | – 1 CV Direct Current
– 1 CV single phase alternating current – 1 KW three-phase alternating current |
Power factor | Variable between 0 and 1 (inductive and capacitive) |
Maximum input voltage | – 250 V Direct Current
– 280 V AC single and three phase |
Maximum intensity | 10 A |
Short-circuit switch | Current variation between 0 and 100% |
Module with integrated Instrumentation through LCD display and magnitude selector push button |
– Voltmeter
– Ammeter – Wattmeter (active, reactive and apparent) – Power Factor Meter – Phase angle meter to measure the angle between voltage and current – Frequency |